Please use this identifier to cite or link to this item: http://hdl.handle.net/1893/8791
Full metadata record
DC FieldValueLanguage
dc.contributor.authorEvans, Josieen_UK
dc.contributor.authorNewton, Ray Wen_UK
dc.contributor.authorRuta, Danny Aen_UK
dc.contributor.authorMacDonald, Thomas Men_UK
dc.contributor.authorStevenson, Richard Jen_UK
dc.contributor.authorMorris, Andrew Den_UK
dc.date.accessioned2014-09-12T13:50:53Z-
dc.date.available2014-09-12T13:50:53Z-
dc.date.issued1999-07-10en_UK
dc.identifier.urihttp://hdl.handle.net/1893/8791-
dc.description.abstractObjectives: To investigate patterns of self monitoring of blood glucose concentration in diabetic patients who use insulin and to determine whether frequency of self monitoring is related to glycaemic control. Setting: Diabetes database, Tayside, Scotland. Subjects: Patients resident in Tayside in 1993­-5 who were using insulin and were registered on the database and diagnosed with insulin dependent (type 1) or non­insulin dependent (type 2) diabetes before 1993. Main outcome measures: Number of glucose monitoring reagent strips dispensed (reagent strip uptake) derived from records of prescriptions. First recorded haemoglobin A1c concentration in the study period, and reagent strips dispensed in the previous 6 months. Results: Among 807 patients with type 1 diabetes, 128 (16%) did not redeem any prescriptions for glucose monitoring reagent strips in the 3 year study period. Only 161 (20%) redeemed prescriptions for enough reagent strips to test glucose daily. The corresponding figures for the 790 patients with type 2 diabetes who used insulin were 162 (21%; no strips) and 131 (17%; daily tests). Reagent strip uptake was influenced both by age and by deprivation category. There was a direct relation between uptake and glycaemic control for 258 patients (with recorded haemoglobin A1c concentrations) with type 1 diabetes. In a linear regression model the decrease in haemoglobin A1c concentration for every extra 180 reagent strips dispensed was 0.7%. For the 290 patients with type 2 diabetes who used insulin there was no such relation. Conclusions: Self monitoring of blood glucose concentration is associated with improved glycaemic control in patients with type 1 diabetes. Regular self monitoring in patients with type 1 and type 2 diabetes is uncommon.en_UK
dc.language.isoenen_UK
dc.publisherBMJ Publishing Groupen_UK
dc.relationEvans J, Newton RW, Ruta DA, MacDonald TM, Stevenson RJ & Morris AD (1999) Frequency of blood glucose monitoring in relation to glycaemic control: observational study with diabetes database. BMJ, 319 (7202), pp. 83-86. https://doi.org/10.1136/bmj.319.7202.83en_UK
dc.rightsPublisher policy allows this work to be made available in this repository. Published in BMJ by BMJ Publishing Group, copyright 1999. The original publication is available at http://www.bmj.com/content/319/7202/83en_UK
dc.titleFrequency of blood glucose monitoring in relation to glycaemic control: observational study with diabetes databaseen_UK
dc.typeJournal Articleen_UK
dc.identifier.doi10.1136/bmj.319.7202.83en_UK
dc.citation.jtitleBMJen_UK
dc.citation.issn1756-1833en_UK
dc.citation.issn0959-8138en_UK
dc.citation.volume319en_UK
dc.citation.issue7202en_UK
dc.citation.spage83en_UK
dc.citation.epage86en_UK
dc.citation.publicationstatusPublisheden_UK
dc.citation.peerreviewedRefereeden_UK
dc.type.statusVoR - Version of Recorden_UK
dc.author.emailjosie.evans@stir.ac.uken_UK
dc.contributor.affiliationHealth Sciences Research - Stirling - LEGACYen_UK
dc.contributor.affiliationUniversity of Dundeeen_UK
dc.contributor.affiliationUniversity of Dundeeen_UK
dc.contributor.affiliationNinewells Hospital & Medical Schoolen_UK
dc.contributor.affiliationNinewells Hospital & Medical Schoolen_UK
dc.contributor.affiliationUniversity of Dundeeen_UK
dc.identifier.isiWOS:000081438200023en_UK
dc.identifier.wtid781489en_UK
dc.contributor.orcid0000-0001-6672-7876en_UK
dcterms.dateAccepted1999-07-10en_UK
dc.date.filedepositdate2012-09-03en_UK
rioxxterms.typeJournal Article/Reviewen_UK
rioxxterms.versionVoRen_UK
local.rioxx.authorEvans, Josie|0000-0001-6672-7876en_UK
local.rioxx.authorNewton, Ray W|en_UK
local.rioxx.authorRuta, Danny A|en_UK
local.rioxx.authorMacDonald, Thomas M|en_UK
local.rioxx.authorStevenson, Richard J|en_UK
local.rioxx.authorMorris, Andrew D|en_UK
local.rioxx.projectInternal Project|University of Stirling|https://isni.org/isni/0000000122484331en_UK
local.rioxx.freetoreaddate2012-09-03en_UK
local.rioxx.licencehttp://www.rioxx.net/licenses/all-rights-reserved|2012-09-03|en_UK
local.rioxx.filenameEvans_1999_Frequency_of_blood_glucose_monitoring.pdfen_UK
local.rioxx.filecount1en_UK
local.rioxx.source0959-8138en_UK
Appears in Collections:Faculty of Health Sciences and Sport Journal Articles

Files in This Item:
File Description SizeFormat 
Evans_1999_Frequency_of_blood_glucose_monitoring.pdfFulltext - Published Version266.87 kBAdobe PDFView/Open


This item is protected by original copyright



Items in the Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

The metadata of the records in the Repository are available under the CC0 public domain dedication: No Rights Reserved https://creativecommons.org/publicdomain/zero/1.0/

If you believe that any material held in STORRE infringes copyright, please contact library@stir.ac.uk providing details and we will remove the Work from public display in STORRE and investigate your claim.