Please use this identifier to cite or link to this item: http://hdl.handle.net/1893/12929
Appears in Collections:Faculty of Health Sciences and Sport Journal Articles
Peer Review Status: Refereed
Title: Potential for reported needlestick injury prevention among healthcare workers through safety device usage and improvement of guideline adherence: expert panel assessment
Author(s): Cullen, B L
Genasi, Fiona
Symington, Ian S
Bagg, Jeremy J
McCreaddie, May
Taylor, Avril
Henry, Matthew J
Hutchinson, Sharon J
Goldberg, David J
Contact Email: may.mccreaddie@stir.ac.uk
Keywords: Needlestick injuries
Healthcare workers
Prevention
Safety devices
Guideline adherence
Nursing
Health and safety
Backache Prevention
Industrial safety.
Issue Date: Aug-2006
Date Deposited: 15-May-2013
Citation: Cullen BL, Genasi F, Symington IS, Bagg JJ, McCreaddie M, Taylor A, Henry MJ, Hutchinson SJ & Goldberg DJ (2006) Potential for reported needlestick injury prevention among healthcare workers through safety device usage and improvement of guideline adherence: expert panel assessment. Journal of Hospital Infection, 63 (4), pp. 445-451. https://doi.org/10.1016/j.jhin.2006.04.008
Abstract: A prospective survey was conducted over six months in order to estimate the proportion of reported occupational needlestick injuries sustained by National Health Service (NHS) Scotland staff that could have been prevented through either safety device introduction, improved guideline adherence, guideline revision or a combination of these. This survey involved the administration of a standard proforma to healthcare workers followed by an expert panel assessment. All acute and primary care NHS Scotland trusts, the Scottish Ambulance Service and the Scottish National Blood Transfusion Service were included. Proforma and expert panel assessment data were available for 64% of injuries (952/1497) reported by healthcare staff. These injuries were all percutaneous. The expert panel concluded that: 56% of all injuries and 80% of venepuncture/injection administration injuries would probably/definitely have been prevented through safety device usage, 52% of all injuries and 56% of venepuncture/injection administration injuries would probably/definitely have been prevented through guideline adherence and 72% of all injuries and 88% of venepuncture/injection administration injuries would probably/definitely have been prevented through either intervention. Multi-factorial analysis indicated that injuries sustained through venepuncture/injection administration were significantly more likely to be prevented through safety device usage [adjusted odds ratio (OR) 5.09, 95% confidence intervals (CI) 3.11-8.31 and adjusted OR 2.70, 95% CI 1.64-4.45, respectively], and significantly less likely to be prevented through guideline adherence (adjusted OR 0.26, 95% CI 0.11-0.60 and adjusted OR 0.31, 95% CI 0.12-0.78, respectively). Injuries sustained after completing procedures were significantly more likely to be prevented through safety device usage and guideline adherence. The study's findings support the need for improvements to staff's adherence to needlestick injury guidelines and appropriate implementation of safety devices for venepuncture and injection administration.
DOI Link: 10.1016/j.jhin.2006.04.008
Rights: The publisher does not allow this work to be made publicly available in this Repository. Please use the Request a Copy feature at the foot of the Repository record to request a copy directly from the author. You can only request a copy if you wish to use this work for your own research or private study.
Licence URL(s): http://www.rioxx.net/licenses/under-embargo-all-rights-reserved

Files in This Item:
File Description SizeFormat 
McCreaddie_2006_Potential_for_reported_needlestick _njury.pdfFulltext - Published Version150.69 kBAdobe PDFUnder Embargo until 3000-01-01    Request a copy

Note: If any of the files in this item are currently embargoed, you can request a copy directly from the author by clicking the padlock icon above. However, this facility is dependent on the depositor still being contactable at their original email address.



This item is protected by original copyright



Items in the Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

The metadata of the records in the Repository are available under the CC0 public domain dedication: No Rights Reserved https://creativecommons.org/publicdomain/zero/1.0/

If you believe that any material held in STORRE infringes copyright, please contact library@stir.ac.uk providing details and we will remove the Work from public display in STORRE and investigate your claim.