Please use this identifier to cite or link to this item: http://hdl.handle.net/1893/12345
Full metadata record
DC FieldValueLanguage
dc.contributor.authorHunter, Angusen_UK
dc.contributor.authorGibson, Alan St Clairen_UK
dc.contributor.authorLambert, Michaelen_UK
dc.contributor.authorNoakes, Timothy Den_UK
dc.date.accessioned2016-08-26T03:41:19Z-
dc.date.available2016-08-26T03:41:19Zen_UK
dc.date.issued2002-05en_UK
dc.identifier.urihttp://hdl.handle.net/1893/12345-
dc.description.abstractPurpose: To determine the most effective electromyographic (EMG) normalization method for cycling fatigue protocols. Methods: Ten healthy subjects performed two 5-s isometric knee extension maximal voluntary contractions (MVC) at a knee joint angle of 60 degrees, two fixed cycle pedal contraction at knee joint angles of 60 degrees (60 degrees A) and 108 degrees (108 degrees A), and a dynamic single maximal revolution of a cycle pedal (1REV). Integrated EMG (IEMG) data were recorded for all contractions and power output recorded during MVC and 1REV. Results: Mean IEMG for MVC was significantly (P less than 0.01) greater than 60 degrees C, 108 degrees C, and 1REV. There were no significant differences between MVC and 1REV power output/EMG relationship. Conclusions: MVC will record a higher IEMG than 60 degrees A, 108 degrees A, and 1REV. As IEMG was greatest during MVC, and the relationship between IEMG and power output was not different between MVC and 1REV, normalization against maximal possible recruitment potential is most likely during MVC.en_UK
dc.language.isoenen_UK
dc.publisherAmerican College of Sports Medicine / Lippincott, Williams & Wilkinsen_UK
dc.relationHunter A, Gibson ASC, Lambert M & Noakes TD (2002) Electromyographic (EMG) normalization method for cycle fatigue protocols. Medicine and Science in Sports and Exercise, 34 (5), pp. 857-861. https://doi.org/10.1097/00005768-200205000-00020en_UK
dc.rightsThe publisher does not allow this work to be made publicly available in this Repository. Please use the Request a Copy feature at the foot of the Repository record to request a copy directly from the author. You can only request a copy if you wish to use this work for your own research or private study.en_UK
dc.rights.urihttp://www.rioxx.net/licenses/under-embargo-all-rights-reserveden_UK
dc.subjectintegrated electromyography (IEMG)en_UK
dc.subjectvoluntary contractionsen_UK
dc.subjectCyclingen_UK
dc.subjectMuscle strength Testingen_UK
dc.subjectMuscle strength Measurement.en_UK
dc.titleElectromyographic (EMG) normalization method for cycle fatigue protocolsen_UK
dc.typeJournal Articleen_UK
dc.rights.embargodate3000-01-01en_UK
dc.rights.embargoreason[Hunter_2002_Electromyographic_normalization_method.pdf] The publisher does not allow this work to be made publicly available in this Repository therefore there is an embargo on the full text of the work.en_UK
dc.identifier.doi10.1097/00005768-200205000-00020en_UK
dc.citation.jtitleMedicine and Science in Sports and Exerciseen_UK
dc.citation.issn1530-0315en_UK
dc.citation.issn0195-9131en_UK
dc.citation.volume34en_UK
dc.citation.issue5en_UK
dc.citation.spage857en_UK
dc.citation.epage861en_UK
dc.citation.publicationstatusPublisheden_UK
dc.citation.peerreviewedRefereeden_UK
dc.type.statusVoR - Version of Recorden_UK
dc.author.emaila.m.hunter1@stir.ac.uken_UK
dc.contributor.affiliationSporten_UK
dc.contributor.affiliationUniversity of Cape Townen_UK
dc.contributor.affiliationUniversity of Cape Townen_UK
dc.contributor.affiliationUniversity of Cape Townen_UK
dc.identifier.isiWOS:000175402700020en_UK
dc.identifier.scopusid2-s2.0-0036236730en_UK
dc.identifier.wtid710159en_UK
dc.contributor.orcid0000-0001-7562-6145en_UK
dcterms.dateAccepted2002-05-31en_UK
dc.date.filedepositdate2013-04-29en_UK
rioxxterms.typeJournal Article/Reviewen_UK
rioxxterms.versionVoRen_UK
local.rioxx.authorHunter, Angus|0000-0001-7562-6145en_UK
local.rioxx.authorGibson, Alan St Clair|en_UK
local.rioxx.authorLambert, Michael|en_UK
local.rioxx.authorNoakes, Timothy D|en_UK
local.rioxx.projectInternal Project|University of Stirling|https://isni.org/isni/0000000122484331en_UK
local.rioxx.freetoreaddate3000-01-01en_UK
local.rioxx.licencehttp://www.rioxx.net/licenses/under-embargo-all-rights-reserved||en_UK
local.rioxx.filenameHunter_2002_Electromyographic_normalization_method.pdfen_UK
local.rioxx.filecount1en_UK
local.rioxx.source0195-9131en_UK
Appears in Collections:Faculty of Health Sciences and Sport Journal Articles

Files in This Item:
File Description SizeFormat 
Hunter_2002_Electromyographic_normalization_method.pdfFulltext - Published Version569.71 kBAdobe PDFUnder Embargo until 3000-01-01    Request a copy


This item is protected by original copyright



Items in the Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

The metadata of the records in the Repository are available under the CC0 public domain dedication: No Rights Reserved https://creativecommons.org/publicdomain/zero/1.0/

If you believe that any material held in STORRE infringes copyright, please contact library@stir.ac.uk providing details and we will remove the Work from public display in STORRE and investigate your claim.