Title: Harnessing solar to power lower-cost air quality sensors
Author(s): McCarron, Amy
Semple, Sean
Blake, Matthew
Balfour, Ronnie
Mills, Jim
Price, Heather D.
Contact Email: heather.price@stir.ac.uk
Keywords: air pollution
air quality
hyperlocal air monitoring
low cost sensor/monitor
solar energy (photovoltaic systems)
Issue Date: 23-Feb-2026
Date Deposited: 24-Feb-2026
Citation: McCarron A, Semple S, Blake M, Balfour R, Mills J & Price HD (2026) Harnessing solar to power lower-cost air quality sensors. <i>Frontiers in Sustainable Cities</i>, 8. https://doi.org/10.3389/frsc.2026.1768135
Abstract: Air quality monitoring networks are essential for characterising spatial and temporal patterns in air pollution concentrations that inform the management of population exposure, but are often spatially sparse, limiting their ability to capture hyperlocal variation in air pollution. Lower-cost air quality sensors are increasingly used to address this challenge by complementing regulatory networks where they exist, extending monitoring into under-represented locations where monitoring is sparse, and establishing networks where monitoring is non-existent. However, deploying such sensors in practice frequently requires bespoke, context-responsive system configurations, particularly where access to power and infrastructure is limited. By deploying a lower-cost particulate matter sensor in a high-latitude context characterised by strong seasonal variability, using a customised solar-powered configuration, the paper consolidates practical considerations for the design and deployment of an off-grid air quality monitoring system, highlighting how design decisions, system trade-offs, and deployment processes could be adapted depending on context. While solar-powered systems can support hyperlocal monitoring, performance and scalability are shaped by seasonal variability, energy storage and charge-control limitations, connectivity-related power demand, siting constraints, and resilience to power interruptions. Deployment also highlighted institutional and governance considerations, including permissions, public space management, and ongoing maintenance burden. Synthesised practical considerations and recommendations are presented to inform the design and deployment of autonomous sensor networks capable of supporting hyperlocal air quality assessment, targeted mitigation, and more actionable decision-making.
DOI Link: 10.3389/frsc.2026.1768135
Rights: © 2026 McCarron, Semple, Blake, Balfour, Mills and Price. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
Licence URL(s): http://creativecommons.org/licenses/by/4.0/

Files in This Item:
File Description SizeFormat 
frsc-8-1768135.pdfFulltext - Published Version1.17 MBAdobe PDFView/Open



This item is protected by original copyright



A file in this item is licensed under a Creative Commons License Creative Commons

Items in the Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

The metadata of the records in the Repository are available under the CC0 public domain dedication: No Rights Reserved https://creativecommons.org/publicdomain/zero/1.0/

If you believe that any material held in STORRE infringes copyright, please contact library@stir.ac.uk providing details and we will remove the Work from public display in STORRE and investigate your claim.