Please use this identifier to cite or link to this item: http://hdl.handle.net/1893/37148
Appears in Collections:Faculty of Health Sciences and Sport Journal Articles
Peer Review Status: Refereed
Title: Use of CPR feedback devices in resuscitation training: A systematic review and meta-analysis of randomized controlled trials
Author(s): Lin, Yiqun
Lockey, Andrew
Donoghue, Aaron
Greif, Robert
Cortegiani, Andrea
Farquharson, Barbara
Siddiqui, Fahad Javaid
Banerjee, Arna
Matsuyama, Tasuku
Cheng, Adam
Contact Email: barbara.farquharson2@stir.ac.uk
Keywords: Resuscitation
CPR Feedback
Training
Basic Life Support
Medical Education
Issue Date: May-2025
Date Deposited: 20-Jun-2025
Citation: Lin Y, Lockey A, Donoghue A, Greif R, Cortegiani A, Farquharson B, Siddiqui FJ, Banerjee A, Matsuyama T & Cheng A (2025) Use of CPR feedback devices in resuscitation training: A systematic review and meta-analysis of randomized controlled trials. <i>Resuscitation Plus</i>, 23, Art. No.: 100939. https://doi.org/10.1016/j.resplu.2025.100939
Abstract: Objectives The use of cardiopulmonary resuscitation (CPR) feedback devices during training is increasing. This review evaluates whether incorporating CPR feedback devices in training improves patient survival, CPR quality in actual resuscitation, skill acquisition and retention after training. Methods This systematic review was part of the continuous evidence evaluation process of the International Liaison Committee on Resuscitation (ILCOR). We searched MEDLINE, EMBASE, and SCOPUS databases from inception to September 30, 2024, including randomized controlled trials (RCTs) in all languages (with an English abstract) comparing CPR training with and without feedback devices. Outcome included patient survival, quality of clinical performance in resuscitation, and CPR skill acquisition and retention. Non-RCT studies, unpublished work without peer review or animal studies were excluded. Risk of bias was assessed using Cochrane tools, and certainty of evidence was graded using the Grading of Recommendations Assessment, development and Evaluation (GRADE) approach. Standardized mean difference (SMD) were calculated and pooled effects were analyzed using random-effects models. PROSPERO CRD42023488130. Results We identified 20 RCTs with 4579 participants. Risks of bias ranged from low to critical (low: 8, moderate: 9, and critical: 3). No studies evaluated the patient survival, clinical performance in resuscitation or cost-effectiveness. Compared to no feedback, using CPR feedback devices during training significantly improved key quality metrics. Pooled effect sizes were 0.76 (95%CI 0.02 – 1.50) for mean compression depth (15 studies), 0.98 (95%CI: 0.10 – 1.87) for depth compliance (16 studies), 0.29 (95%CI: 0.10 – 0.48) for mean rate (17 studies), 0.44 (95%CI: 0.23 – 0.66) for rate compliance (9 studies), and 0.53 (95%CI: 0.31 – 0.75) for recoil compliance (10 studies) in favour of using feedback devices during training. Heterogeneity was large (I2 > 50%) in all analyses. Planned subgroup analyses revealed no statistically significant interaction between healthcare professionals and laypersons. Using the GRADE approach, the certainty of evidence was downgraded for certain outcomes due to critical risk of bias for 3 studies and inconsistency but upgraded for strong association. Conclusion The use of CPR feedback devices during resuscitation training improves key quality metrics of CPR performance, with moderate to high certainty of evidence. However, further studies are needed to evaluate the impact on cost-effectiveness, clinical performance and patient outcomes.
DOI Link: 10.1016/j.resplu.2025.100939
Licence URL(s): http://creativecommons.org/licenses/by-nc-nd/4.0/

Files in This Item:
File Description SizeFormat 
1-s2.0-S2666520425000761-main.pdfFulltext - Published Version559.69 kBAdobe PDFView/Open



This item is protected by original copyright



A file in this item is licensed under a Creative Commons License Creative Commons

Items in the Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

The metadata of the records in the Repository are available under the CC0 public domain dedication: No Rights Reserved https://creativecommons.org/publicdomain/zero/1.0/

If you believe that any material held in STORRE infringes copyright, please contact library@stir.ac.uk providing details and we will remove the Work from public display in STORRE and investigate your claim.